GDC2-63 AC MCB Overview
O GDC2-63 AC MCB is a compact miniature circuit breaker designed for overload and short-circuit protection in low-voltage AC electrical systems. With rated currents from 1A to 63A, a rated breaking capacity of 6kA, and multiple pole configurations, the series can be used in residential distribution boards, commercial electrical panels, industrial control cabinets and OEM equipment.
O GDC2-63 AC MCB is available in 1P, 2P, 3P and 4P versions, allowing the same product family to cover both single-phase and three-phase protection requirements. Rated voltage reaches 240/415V AC, with a frequency of 50/60 Hz.
Three thermo-magnetic trip characteristics are available:
- B Curve
- C Curve
- D Curve
These trip curves allow the GDC2-63 series to be matched to different load conditions. B curve models are suitable for circuits with lower inrush current, C curve models are commonly used for general distribution and equipment circuits, while D curve versions can be selected for loads with higher starting currents.
Compared with the GDC1-63 series, the GDC2-63 AC MCB provides a higher 6kA breaking capacity, making it suitable for installations where a greater short-circuit interruption capability is required.
The breaker is designed for standard 35mm DIN rail mounting, making installation and replacement straightforward inside modular electrical panels.
Características do produto
O GDC2-63 AC MCB provides a rated short-circuit breaking capacity of 6000A.
This higher breaking capability makes the series suitable for residential, commercial and industrial distribution systems where prospective fault current may exceed the capability of a standard 4.5kA MCB.
Available current ratings include:
1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A.
This wide selection allows the GDC2-63 AC MCB to protect different branch circuits, loads and electrical equipment.
The GDC2-63 series is available in:
- 1P
- 2P
- 3P
- 4P
Multiple pole options simplify product selection for different single-phase and three-phase installations.The GDC2-63 AC MCB supports B, C and D thermo-magnetic characteristics, making the series adaptable to different load profiles and inrush-current requirements.A built-in contact position indicator provides a clear visual reference of breaker status, helping technicians during inspection and maintenance.The breaker is designed for mounting on a standard 35mm DIN rail, supporting compact installation in modular distribution and control equipment.
Especificações Técnicas
| Parâmetro | Especificações |
|---|---|
| Marca | GA&DA |
| Modelo | GDC2-63 |
| Tipo de produto | AC Miniature Circuit Breaker |
| Rated Current | 1A–63A |
| Pole Options | 1P / 2P / 3P / 4P |
| Tensão nominal | 240V / 415V AC |
| Rated Frequency | 50/60 Hz |
| Insulation Voltage Ui | 500 V |
| Impulse Withstand Voltage Uimp | 4kV |
| Breaking Capacity | 6kA / 6000A |
| Trip Curve | B / C / D |
| Dielectric Test Voltage | 2kV |
| Electrical Life | 4,000 operations |
| Mechanical Life | 10,000 operations |
| Protection Class | IP20 |
| Contact Position Indicator | Sim |
| Reference Temperature | 30°C |
| Ambient Temperature | -5°C to +40°C |
| Storage Temperature | -25°C to +70°C |
| Terminal Capacity | Up to 25mm² |
| Tightening Torque | 3.0 N·m |
| Montagem | 35mm DIN Rail |
| Connection | Top and Bottom |
| Standard | IEC/EN 60898-1 |
Dimension Figure

Applications of GDC2-63 AC MCB
O GDC2-63 AC MCB is suitable for a wide range of low-voltage electrical protection applications, including:
- Residential distribution boards
- Commercial electrical panels
- Armários de controlo industrial
- Lighting circuits
- Power distribution systems
- Machinery control circuits
- HVAC electrical equipment
- Building electrical installations
- OEM electrical assemblies
- Small motor and equipment circuits
The combination of a 6kA breaking capacity, multiple pole options and B/C/D trip characteristics makes the GDC2-63 suitable for both general-purpose and more demanding AC protection applications.
Selecting a GDC2-63 AC MCB
When selecting a GDC2-63 AC MCB, engineers should consider more than the rated current.
Important selection factors include:
- Load current
- Cable capacity
- Tensão do sistema
- Number of poles
- Prospective short-circuit current
- Required trip curve
- Upstream and downstream protection coordination
For standard distribution circuits, C curve is commonly used. B curve may be preferred for lower-inrush loads, while D curve can be selected where equipment produces higher starting currents.
The selected GDC2-63 breaker should always match the conductor capacity and electrical characteristics of the protected circuit.
Why Choose GA&DA GDC2-63 AC MCB?
O GDC2-63 AC MCB combines a broad current range with a higher 6kA breaking capacity in a compact DIN rail design.
As principais vantagens incluem:
- 1A–63A current range
- 6kA breaking capacity
- 1P / 2P / 3P / 4P configurations
- B / C / D trip curves
- 240V / 415V AC applications
- IEC/EN 60898-1 standard
- Contact position indicator
- 35mm DIN rail mounting
- Up to 25mm² terminal capacity
- Suitable for residential and industrial applications
- Suitable for distributors and OEM manufacturers
- Bulk and project purchasing support
For wholesalers, panel builders and electrical equipment manufacturers, the GDC2-63 provides a flexible MCB platform that can cover a wide range of protection requirements with one consistent product family.
Perguntas frequentes
What is the maximum current rating of the GDC2-63 AC MCB?
The GDC2-63 AC MCB is available with rated currents up to 63A.
What is the breaking capacity?
The GDC2-63 has a rated breaking capacity of 6kA.
Which pole configurations are available?
The series supports 1P, 2P, 3P and 4P configurations.
Which trip curves are available?
The GDC2-63 AC MCB is available with B, C and D curves.
What voltage does the GDC2-63 support?
The series is designed for 240V / 415V AC systems.