GA&DA GDC2-63 63A 6kA AC Miniature Circuit Breaker

GA&DA GDC2-63 AC MCB supports 1A-63A, 1P-4P, B/C/D trip curves and 6kA breaking capacity for reliable residential, commercial and industrial AC protection.

  • Courant nominal : 1A–63A
  • Options de poteaux : 1P / 2P / 3P / 4P
  • Tension nominale : 240V / 415V AC
  • Fréquence nominale : 50/60 Hz
Partager sur :

GDC2-63 AC MCB Overview

Le GDC2-63 AC MCB is a compact miniature circuit breaker designed for overload and short-circuit protection in low-voltage AC electrical systems. With rated currents from 1 A à 63 A, a rated breaking capacity of 6 kA, and multiple pole configurations, the series can be used in residential distribution boards, commercial electrical panels, industrial control cabinets and OEM equipment.

Le GDC2-63 AC MCB est disponible en 1P, 2P, 3P et 4P versions, allowing the same product family to cover both single-phase and three-phase protection requirements. Rated voltage reaches 240/415V AC, with a frequency of 50/60 Hz.

Three thermo-magnetic trip characteristics are available:

  • B Curve
  • C Curve
  • D Curve

These trip curves allow the GDC2-63 series to be matched to different load conditions. B curve models are suitable for circuits with lower inrush current, C curve models are commonly used for general distribution and equipment circuits, while D curve versions can be selected for loads with higher starting currents.

Compared with the GDC1-63 series, the GDC2-63 AC MCB provides a higher Capacité de coupure de 6 kA, making it suitable for installations where a greater short-circuit interruption capability is required.

The breaker is designed for standard Montage sur rail DIN de 35 mm, making installation and replacement straightforward inside modular electrical panels.

Caractéristiques du produit

Le GDC2-63 AC MCB provides a rated short-circuit breaking capacity of 6 000 A.

This higher breaking capability makes the series suitable for residential, commercial and industrial distribution systems where prospective fault current may exceed the capability of a standard 4.5kA MCB.

Available current ratings include:

1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A.

This wide selection allows the GDC2-63 AC MCB to protect different branch circuits, loads and electrical equipment.

The GDC2-63 series is available in:

  • 1P
  • 2P
  • 3P
  • 4P

Multiple pole options simplify product selection for different single-phase and three-phase installations.The GDC2-63 AC MCB supports B, C and D thermo-magnetic characteristics, making the series adaptable to different load profiles and inrush-current requirements.A built-in contact position indicator provides a clear visual reference of breaker status, helping technicians during inspection and maintenance.The breaker is designed for mounting on a standard 35mm DIN rail, supporting compact installation in modular distribution and control equipment.

Caractéristiques techniques

ParamètreCaractéristiques techniques
MarqueGA&DA
ModèleGDC2-63
Type de produitDisjoncteur miniature CA
Courant nominal1A–63A
Options de poteaux1P / 2P / 3P / 4P
Tension nominale240V / 415V AC
Fréquence nominale50/60 Hz
Insulation Voltage Ui500 V
Impulse Withstand Voltage Uimp4 kV
Capacité de rupture6kA / 6000A
Trip CurveB / C / D
Tension d'essai diélectrique2 kV
Durée de vie électrique4,000 operations
Durée de vie mécanique10,000 operations
Classe de protectionIP20
Contact Position IndicatorOui
Reference Temperature30°C
Température ambiantede -5 °C à +40 °C
Température de stockagede -25 °C à +70 °C
Terminal CapacityUp to 25mm²
Couple de serrage3.0 N·m
MontageRail DIN de 35 mm
ConnexionTop and Bottom
StandardIEC/EN 60898-1

Dimensions

GDC2 63

Applications of GDC2-63 AC MCB

Le GDC2-63 AC MCB is suitable for a wide range of low-voltage electrical protection applications, including:

  • Tableaux de distribution résidentiels
  • Tableaux électriques commerciaux
  • Armoires de commande industrielles
  • Circuits d'éclairage
  • Power distribution systems
  • Machinery control circuits
  • HVAC electrical equipment
  • Building electrical installations
  • Ensembles électriques OEM
  • Small motor and equipment circuits

The combination of a Capacité de coupure de 6 kA, multiple pole options and B/C/D trip characteristics makes the GDC2-63 suitable for both general-purpose and more demanding AC protection applications.

Selecting a GDC2-63 AC MCB

When selecting a GDC2-63 AC MCB, engineers should consider more than the rated current.

Important selection factors include:

  • Load current
  • Cable capacity
  • System voltage
  • Number of poles
  • Prospective short-circuit current
  • Required trip curve
  • Upstream and downstream protection coordination

For standard distribution circuits, Courbe en C is commonly used. B curve may be preferred for lower-inrush loads, while D curve can be selected where equipment produces higher starting currents.

The selected GDC2-63 breaker should always match the conductor capacity and electrical characteristics of the protected circuit.

Why Choose GA&DA GDC2-63 AC MCB?

Le GDC2-63 AC MCB combines a broad current range with a higher 6kA breaking capacity in a compact DIN rail design.

Parmi les principaux avantages, on peut citer :

  • 1A–63A current range
  • Capacité de coupure de 6 kA
  • 1P / 2P / 3P / 4P configurations
  • B / C / D trip curves
  • 240V / 415V AC applications
  • IEC/EN 60898-1 standard
  • Contact position indicator
  • Montage sur rail DIN de 35 mm
  • Up to 25mm² terminal capacity
  • Suitable for residential and industrial applications
  • Suitable for distributors and OEM manufacturers
  • Bulk and project purchasing support

For wholesalers, panel builders and electrical equipment manufacturers, the GDC2-63 provides a flexible MCB platform that can cover a wide range of protection requirements with one consistent product family.

FAQ

What is the maximum current rating of the GDC2-63 AC MCB?

The GDC2-63 AC MCB is available with rated currents up to 63A.

What is the breaking capacity?

The GDC2-63 has a rated breaking capacity of 6kA.

Which pole configurations are available?

The series supports 1P, 2P, 3P and 4P configurations.

Which trip curves are available?

The GDC2-63 AC MCB is available with B, C and D curves.

What voltage does the GDC2-63 support?

The series is designed for 240V / 415V AC systems.

Demander un devis

Indiquez-nous vos spécifications, la quantité souhaitée ou le cas d'utilisation, et nous vous proposerons un devis sur mesure.

+86-15979993994 Téléphone info@cngandian.com E-mail