GDC4-63 AC MCB Overview
Le GDC4-63 AC MCB is a compact miniature circuit breaker designed for overload and short-circuit protection in low-voltage AC distribution systems. With rated currents from 1 A à 63 A, a Capacité de coupure de 6 kA, and multiple pole configurations, the series provides a flexible protection solution for residential, commercial and light industrial electrical installations.
Le GDC4-63 AC MCB est disponible en 1P, 2P, 3P et 4P versions, allowing the same product family to be used in both single-phase and three-phase systems. Rated operating voltage is 240/415V AC, with a rated frequency of 50/60 Hz.
Three thermo-magnetic trip curves are available:
- B Curve
- C Curve
- D Curve
These curve options allow the GDC4-63 AC MCB to be matched to different load characteristics. B curve is suitable for circuits with relatively low inrush current, C curve is commonly used for general distribution and equipment circuits, while D curve can be selected for loads with higher starting current.
The GDC4-63 uses a compact modular housing with a clearly visible operating handle and contact position indicator. This makes breaker status easy to check during routine inspection and maintenance.
Designed for standard Montage sur rail DIN de 35 mm, le GDC4-63 AC MCB can be installed efficiently in distribution boards, control panels and OEM electrical assemblies.
Caractéristiques du produit
6kA Breaking Capacity
Le GDC4-63 AC MCB offre une capacité de coupure nominale de 6 000 A, helping interrupt short-circuit currents within its specified operating range.
This makes the series suitable for installations that require higher interruption capability than basic 4.5kA MCB products.
1A to 63A Current Range
Available current ratings include:
1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A.
The wide current range allows the GDC4-63 AC MCB to cover lighting circuits, socket circuits, distribution feeders and equipment protection.
1P / 2P / 3P / 4P Configurations
The GDC4-63 series is available in:
- 1P
- 2P
- 3P
- 4P
Different pole options simplify product selection for different electrical system layouts.
B / C / D Trip Curves
Le GDC4-63 AC MCB supports B, C and D thermo-magnetic characteristics, allowing engineers to select a curve according to normal load current and expected inrush current.
Contact Position Indicator
A built-in contact position indicator provides clear visual identification of breaker status, helping improve inspection efficiency.
DIN Rail Mounting
The breaker is designed for 35mm DIN rail installation, supporting quick assembly and replacement inside modular electrical panels.
Caractéristiques techniques
| Paramètre | Caractéristiques techniques |
|---|---|
| Marque | GA&DA |
| Modèle | GDC4-63 |
| Type de produit | Disjoncteur miniature CA |
| Courant nominal | 1A–63A |
| Options de poteaux | 1P / 2P / 3P / 4P |
| Tension nominale | 240/415V AC |
| Fréquence nominale | 50/60 Hz |
| Insulation Voltage Ui | 500 V |
| Impulse Withstand Voltage Uimp | 4 kV |
| Capacité de rupture | 6kA / 6000A |
| Trip Curve | B / C / D |
| Tension d'essai diélectrique | 2 kV |
| Durée de vie électrique | 4,000 operations |
| Durée de vie mécanique | 10,000 operations |
| Classe de protection | IP20 |
| Contact Position Indicator | Oui |
| Reference Temperature | 30°C |
| Température ambiante | de -5 °C à +40 °C |
| Température de stockage | de -25 °C à +70 °C |
| Connexion au terminal | Câble / Barre omnibus de type U / Barre omnibus à broches |
| Terminal Capacity | Up to 25mm² |
| Couple de serrage | 3.0 N·m |
| Montage | Rail DIN de 35 mm |
| Connexion | Top and Bottom |
| Standard | IEC/EN 60898-1 |
Dimensions

Applications of GDC4-63 AC MCB
Le GDC4-63 AC MCB is suitable for a variety of low-voltage AC protection applications, including:
- Tableaux de distribution résidentiels
- Tableaux électriques commerciaux
- Circuits d'éclairage
- Socket circuits
- Office building distribution
- Small industrial control cabinets
- HVAC electrical systems
- Panneaux de protection des équipements
- Ensembles électriques OEM
- General power distribution
The combination of 6kA breaking capacity, multiple pole options and B/C/D curves makes the GDC4-63 suitable for both general branch-circuit protection and customized panel applications.
Selecting a GDC4-63 AC MCB
When selecting a GDC4-63 AC MCB, engineers should consider the rated current, conductor capacity, system voltage, number of poles and expected short-circuit current.
Trip curve selection is also important. B curve can be used for lower-inrush loads, C curve is commonly used for general distribution, and D curve is better suited to circuits with higher starting currents.
The selected breaker rating should remain coordinated with the protected conductor and upstream protection device.
Why Choose GA&DA GDC4-63 AC MCB?
Le GDC4-63 AC MCB combines a compact structure with multiple electrical configurations, making it practical for distributors, panel builders and OEM manufacturers.
Parmi les principaux avantages, on peut citer :
- 1A–63A current range
- Capacité de coupure de 6 kA
- 1P / 2P / 3P / 4P versions
- B / C / D trip curves
- 240/415V AC applications
- IEC/EN 60898-1 compliance
- Indication de la position du contact
- Standard DIN rail installation
- Up to 25mm² terminal capacity
- Suitable for residential and commercial systems
- Suitable for distributor stock
- Prise en charge des commandes OEM et en gros
For electrical wholesalers and panel manufacturers, the GDC4-63 AC MCB offers a consistent product platform that can cover multiple current, pole and trip-curve requirements.