Descripción
GDDC4-63 DC MCB Overview
El GDDC4-63 DC MCB es un producto de alto rendimiento nonpolarity DC miniature circuit breaker developed for overload and short-circuit protection in photovoltaic, energy storage and other low-voltage DC systems. With rated currents from 10A to 63A and system voltage configurations extending up to 1000 V CC, it provides a flexible protection solution for modern DC distribution equipment.
A key advantage of the GDDC4-63 DC MCB is its nonpolarity design. Conventional polarized DC circuit breakers require careful attention to positive and negative terminal orientation. The nonpolarity structure provides greater wiring flexibility during panel assembly and field installation, which is particularly useful in photovoltaic and energy-storage applications.
The series supports Configuraciones de 1P, 2P, 3P y 4P, corresponding to different DC voltage levels. Standard configurations include 1P 250V DC, 2P 500V DC, 3P 750V DC and 4P 1000V DC.
With a rated breaking capacity of 6000A / 10000A, the GDDC4-63 DC MCB is positioned above lower-breaking-capacity models for applications requiring stronger fault-current interruption performance. It complies with IEC/EN60947-2 and supports B, C and D thermo-magnetic trip characteristics.
Características del producto
Nonpolarity DC Design
El GDDC4-63 DC MCB features a nonpolarity design that simplifies DC wiring and reduces restrictions related to positive and negative connection orientation.
Up to 10kA Breaking Capacity
A rated breaking capacity of 6000A / 10000A provides enhanced short-circuit interruption capability for demanding DC protection systems.
10A to 63A Current Range
Available rated currents include:
10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A.
This allows the GDDC4-63 series to cover multiple photovoltaic and industrial DC circuit requirements.
1P / 2P / 3P / 4P Configurations
The complete GDDC4-63 DC MCB family supports:
- 1P – 250V DC
- 2P – 500V DC
- 3P – 750V DC
- 4P – 1000V DC
B, C and D Trip Curves
B, C and D thermo-magnetic characteristics are available for matching different load and inrush-current conditions.
Instalación en carril DIN
The compact modular structure is designed for standard 35mm DIN rail mounting, simplifying integration into PV combiner boxes and DC distribution cabinets.
Especificaciones técnicas
| Parámetro | Especificaciones |
|---|---|
| Marca | GA&DA |
| Modelo | GDDC4-63 |
| Tipo de producto | Nonpolarity DC Miniature Circuit Breaker |
| Corriente nominal | 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A |
| Opciones de mástil | 1P / 2P / 3P / 4P |
| Rated Voltage Ue | 1P: 250V / 2P: 500V / 3P: 750V / 4P: 1000V DC |
| Insulation Voltage Ui | 1000V |
| Frecuencia nominal | 50/60 Hz |
| Rated Breaking Capacity | 6000A / 10000A |
| Impulse Withstand Voltage Uimp | 8 kV |
| Dielectric Test Voltage | 2kV |
| Trip Curve | B / C / D |
| Electrical Life | 8,000 operations |
| Mechanical Life | 10,000 operations |
| Contact Position Indicator | Sí |
| Protection Class | IP20 |
| Reference Temperature | 30°C |
| Ambient Temperature | -5°C to +40°C |
| Storage Temperature | -25°C to +70°C |
| Terminal Connection | Cable / U-type busbar / Pin-type busbar |
| Max. Cable Size | 25mm² |
| Tightening Torque | 2.5 N·m |
| Montaje | 35mm DIN Rail |
| Connection | Top and Bottom |
| Estándar | IEC/EN60947-2 |
| Auxiliary Contact | Sí |
| Alarm Contact | Sí |
| Shunt Release | Sí |
| Under Voltage Release | Sí |
Applications of GDDC4-63 DC MCB
El GDDC4-63 DC MCB is suitable for DC systems requiring reliable protection and flexible wiring arrangements.
Entre las aplicaciones típicas se incluyen:
- Solar photovoltaic systems
- Cajas de conexión fotovoltaicas
- Solar inverter DC circuits
- Sistemas de almacenamiento de energía en baterías
- DC distribution cabinets
- Charging equipment
- Communication power systems
- Industrial DC control systems
- Renewable energy equipment
- OEM electrical panels
The combination of nonpolarity wiring and up to 10kA breaking capacity makes the GDDC4-63 DC MCB especially suitable for higher-performance photovoltaic and industrial DC protection applications.
Why Choose GA&DA GDDC4-63 DC MCB?
El GDDC4-63 DC MCB provides a stronger protection specification than conventional lower-breaking-capacity DC miniature circuit breakers while retaining a compact DIN rail format.
Entre las principales ventajas se incluyen:
- Nonpolarity wiring design
- Up to 10kA breaking capacity
- Rated current from 10A to 63A
- 1P / 2P / 3P / 4P options
- Voltage configurations up to 1000 V CC
- B / C / D trip curves
- IEC/EN60947-2 compliance
- Tensión de impulso soportada de 8 kV
- Compact DIN rail mounting
- Accessory expansion available
- Suitable for photovoltaic and energy-storage systems
- OEM, distributor and project purchasing support
For wholesalers, solar equipment manufacturers and panel builders, the GDDC4-63 DC MCB provides a versatile DC circuit protection platform for different voltage and current requirements.
Preguntas frecuentes
What is the main advantage of the GDDC4-63 DC MCB?
The GDDC4-63 DC MCB uses a nonpolarity design, providing greater flexibility when wiring DC circuits.
What breaking capacity does the GDDC4-63 provide?
The series is rated at 6000A / 10000A, depending on the applicable configuration.
What current ratings are available?
The GDDC4-63 DC MCB is available in 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A.
¿Qué configuraciones de mástiles hay disponibles?
The complete series includes 1P, 2P, 3P and 4P configurations.
What is the maximum rated voltage?
The 4P GDDC4-63 DC MCB supports rated voltage up to 1000V DC.
Solicitar presupuesto
Indíquenos sus especificaciones, la cantidad o el ámbito de aplicación, y le enviaremos un presupuesto a medida.