قاطع الدائرة المصغر GA&DA GDC2-63 63 أمبير 6 كيلو أمبير تيار متردد

GA&DA GDC2-63 AC MCB supports 1A-63A, 1P-4P, B/C/D trip curves and 6kA breaking capacity for reliable residential, commercial and industrial AC protection.

  • التيار المقنن: 1A–63A
  • خيارات الأعمدة: 1P / 2P / 3P / 4P
  • الجهد المقنن: 240V / 415V AC
  • Rated Frequency: 50/60 هرتز
مشاركة على:

GDC2-63 AC MCB Overview

الـ GDC2-63 AC MCB is a compact miniature circuit breaker designed for overload and short-circuit protection in low-voltage AC electrical systems. With rated currents from 1A to 63A, a rated breaking capacity of 6kA, and multiple pole configurations, the series can be used in residential distribution boards, commercial electrical panels, industrial control cabinets and OEM equipment.

الـ GDC2-63 AC MCB is available in 1P, 2P, 3P and 4P versions, allowing the same product family to cover both single-phase and three-phase protection requirements. Rated voltage reaches 240/415V AC, with a frequency of 50/60 هرتز.

Three thermo-magnetic trip characteristics are available:

  • B Curve
  • C Curve
  • D Curve

These trip curves allow the GDC2-63 series to be matched to different load conditions. B curve models are suitable for circuits with lower inrush current, C curve models are commonly used for general distribution and equipment circuits, while D curve versions can be selected for loads with higher starting currents.

Compared with the GDC1-63 series, the GDC2-63 AC MCB provides a higher 6kA breaking capacity, making it suitable for installations where a greater short-circuit interruption capability is required.

The breaker is designed for standard 35mm DIN rail mounting, making installation and replacement straightforward inside modular electrical panels.

ميزات المنتج

الـ GDC2-63 AC MCB provides a rated short-circuit breaking capacity of 6000A.

This higher breaking capability makes the series suitable for residential, commercial and industrial distribution systems where prospective fault current may exceed the capability of a standard 4.5kA MCB.

Available current ratings include:

1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A.

This wide selection allows the GDC2-63 AC MCB to protect different branch circuits, loads and electrical equipment.

The GDC2-63 series is available in:

  • 1P
  • 2P
  • 3P
  • 4P

Multiple pole options simplify product selection for different single-phase and three-phase installations.The GDC2-63 AC MCB supports B, C and D thermo-magnetic characteristics, making the series adaptable to different load profiles and inrush-current requirements.A built-in contact position indicator provides a clear visual reference of breaker status, helping technicians during inspection and maintenance.The breaker is designed for mounting on a standard 35mm DIN rail, supporting compact installation in modular distribution and control equipment.

المواصفات الفنية

المعلمةالمواصفات
العلامة التجاريةGA&DA
الطرازGDC2-63
نوع المنتجAC Miniature Circuit Breaker
التيار المقنن1A–63A
خيارات الأعمدة1P / 2P / 3P / 4P
الجهد المقنن240V / 415V AC
التردد المحدد50/60 هرتز
Insulation Voltage Ui500V
Impulse Withstand Voltage Uimp4kV
Breaking Capacity6kA / 6000A
Trip CurveB / C / D
Dielectric Test Voltage2 كيلو فولت
Electrical Life4,000 operations
العمر التشغيلي10,000 عملية
Protection ClassIP20
Contact Position Indicatorنعم
Reference Temperature30 درجة مئوية
Ambient Temperatureمن -5 درجة مئوية إلى +40 درجة مئوية
Storage Temperatureمن -25 درجة مئوية إلى +70 درجة مئوية
Terminal CapacityUp to 25mm²
Tightening Torque3.0 N·m
التركيب35mm DIN Rail
الاتصالTop and Bottom
قياسيIEC/EN 60898-1

Dimension Figure

GDC2 63

Applications of GDC2-63 AC MCB

الـ GDC2-63 AC MCB is suitable for a wide range of low-voltage electrical protection applications, including:

  • Residential distribution boards
  • Commercial electrical panels
  • Industrial control cabinets
  • Lighting circuits
  • Power distribution systems
  • Machinery control circuits
  • HVAC electrical equipment
  • Building electrical installations
  • OEM electrical assemblies
  • Small motor and equipment circuits

The combination of a 6kA breaking capacity, multiple pole options and B/C/D trip characteristics makes the GDC2-63 suitable for both general-purpose and more demanding AC protection applications.

Selecting a GDC2-63 AC MCB

When selecting a GDC2-63 AC MCB, engineers should consider more than the rated current.

Important selection factors include:

  • Load current
  • سعة الكابل
  • جهد النظام
  • Number of poles
  • Prospective short-circuit current
  • Required trip curve
  • Upstream and downstream protection coordination

For standard distribution circuits, C curve is commonly used. B curve may be preferred for lower-inrush loads, while D curve can be selected where equipment produces higher starting currents.

The selected GDC2-63 breaker should always match the conductor capacity and electrical characteristics of the protected circuit.

Why Choose GA&DA GDC2-63 AC MCB?

الـ GDC2-63 AC MCB combines a broad current range with a higher 6kA breaking capacity in a compact DIN rail design.

ومن بين المزايا الرئيسية ما يلي:

  • 1A–63A current range
  • 6kA breaking capacity
  • 1P / 2P / 3P / 4P configurations
  • B / C / D trip curves
  • 240V / 415V AC applications
  • IEC/EN 60898-1 standard
  • مؤشر موضع التلامس
  • 35mm DIN rail mounting
  • Up to 25mm² terminal capacity
  • Suitable for residential and industrial applications
  • Suitable for distributors and OEM manufacturers
  • Bulk and project purchasing support

For wholesalers, panel builders and electrical equipment manufacturers, the GDC2-63 provides a flexible MCB platform that can cover a wide range of protection requirements with one consistent product family.

الأسئلة الشائعة

What is the maximum current rating of the GDC2-63 AC MCB?

The GDC2-63 AC MCB is available with rated currents up to 63A.

What is the breaking capacity?

The GDC2-63 has a rated breaking capacity of 6kA.

Which pole configurations are available?

The series supports 1P, 2P, 3P and 4P configurations.

Which trip curves are available?

The GDC2-63 AC MCB is available with B, C and D curves.

What voltage does the GDC2-63 support?

The series is designed for 240V / 415V AC systems.

طلب عرض أسعار

أخبرنا بالمواصفات أو الكمية أو سيناريو الاستخدام، وسنرد عليك بعرض أسعار مخصص.

+86-15979993994 الهاتف info@cngandian.com البريد الإلكتروني